Gadong Taohy

KYORITSU 4120A PDF

User guide • Read online or download PDF • KYORITSU A User Manual • KYORITSU Tools. Get KYORITSU A User guide. Get all KYORITSU manuals!. Find great deals for Kyoritsu Digital Loop Tester Model A. Shop with confidence on eBay!.

Author: Kazrahn Kigarisar
Country: Saint Kitts and Nevis
Language: English (Spanish)
Genre: Travel
Published (Last): 10 July 2013
Pages: 263
PDF File Size: 3.12 Mb
ePub File Size: 14.11 Mb
ISBN: 871-5-90796-682-2
Downloads: 45090
Price: Free* [*Free Regsitration Required]
Uploader: Kagalabar

Or point us to the URL where the manual is located. Add to Wishlist Add to Compare Share. Be the first to review this product Ask Question. We integrate globally recognized quality electronic testing and measurement requirements. Add to Cart Qty: Large custom digital display readout. Such metalwork may become live for the duration of the test.

We source consumer electronics, electrical engineering tools and other electronic products. Always treat it with the greatest of respect and care. Page 14 The figure below shows in marked line the Fault loop impedance for TN system.

Get the item you ordered or get your money back. Tell us about it. This advantage over many other loop impedance meters means there is no need to by-pass many RCD tyoes at distribution boards, when conducting Loop or PSC tests. Custom microprocessor controlled for highest accuracy and reliability.

Don’t see a manual you are looking for? One of the significant features of this model is the D-Lok circuit that permits loop impedance testing without tripping some types of RCD installed in the circuit being loop tested.

  DESPRENDIMIENTO COROIDEO PDF

Analogue Multimeters Digital Multimeters Accessories. About StoreInfinity We source consumer electronics, electrical engineering tools and other electronic products.

This convenient test instrument is capable of measuring fault loop impedance within the wiring circuit directly at the power outlet. The cause of the fault must be investigated and rectified.

No part of this material may be reproduced, translated, transmitted, framed or stored in a retrieval system for public or private use without the written permission of the publisher. Tags Add Your Tags: Newsletter sign-up The latest products and news delivered to your inbox. The figure below shows in marked line the Fault loop impedance for TN system.

In fact the Zs of 1. Featured Category Find more Fluke products,You can use side bar filter to look for your need easier and fast.

Page 17 Max value of Zs for this example is 2. You have no items in your shopping cart.

It is able to measure low loop resistance to a resolution of 0. Max value of Zs for this example is 2. Failure to follow these instruction can cause hazards to the user. JavaScript seems to be disabled in your browser. Contact Test and Tag Supplies.

The Kyoritsu A loop impedance meter has automatic lock-out if test resister overheats. It is fundamental for this example to test also the RCD to ensure that operation takes place quickly enough to respect the safety requirements.

  CISCO SRW2024 PDF

KYORITSU A : User guide

Measures low loop resistances resolution of 0. The cover can be detached and put on the back side of the main body during measurement. Visual indication of reversed phase and neutral wiring at socket. You must have JavaScript enabled in your browser to utilize the functionality of this website. All material on this site is subject to copyright.

KYORITSU 4120A User Manual

Via our supply chain management and product delivery to the customer’s local repository, kykritsu ensure our customers get affordable prices, fast shipping and a logistics localized service Support Email support storeinfinity.

Every circuit must be tested to make sure that the fault loop impedance does not exceed that specified for the over current protection device concerned. Rating A 6 10 16 20 25 32 40 50 63 80 Disconnecting time 5s Disconnecting time 0.

This mode is cancelled whenever the test button is pressed. The RCD could trip during the tests also with model A.

Kyoritsu A Loop Impendance Tester. Therefore, read through these operating instructions before using the instrument. This instruction manual contains warnings and safety rules which must be observed by the user to ensure safe operation kyroitsu the instrument and retain it in safe condition.